The Generator 125A Manual Transfer Switch Single Phase.

Make the most of your generator by adding a 125A manual transfer switch (MTS) single phase for added security and peace of mind. This mains to generator manual changeover switch enables the user to manually control when the power from the generator is to be used. Usually in situations like a power cut or blackout. You can choose to use your manual transfer switch to power either the entire load centre or a select few

...

Make the most of your generator by adding a 125A manual transfer switch (MTS) single phase for added security and peace of mind. This mains to generator manual changeover switch enables the user to manually control when the power from the generator is to be used. Usually in situations like a power cut or blackout. You can choose to use your manual transfer switch to power either the entire load centre or a select few circuits.

How Does a 125A Manual Transfer Switch Single Phase Work?

This transfer switch should be permanently installed close to the mains incoming supply to your building. In normal operation the load is supplied by the mains in the usual way but when the mains power is lost everything will go dark if you have a manual transfer switch.

You will have to get your torch and go out to the generator to start it manually and connect it to the manual transfer switch. Then you will need to switch your home or business over to receive power from the generator. When mains power comes back on, you will need to manually switch the power back to the mains and turn off the generator.

General Specification of the 125A Manual Transfer Switch Single Phase includes:

125A Changeover switch – single phase 4 module IP20 enclosure c/w Flip Lid

125 amp, 230 volt, changeover switch supplied with busbar
2 position switch to transfer between mains and back-up generator
2 normally open and 2 normally closed contacts
IP20 rated steel enclosure c/w Flip Lid

BS EN60974-3 Compliant

Dimensions –

225mm (H) x 115mm (W) x 85mm (D) – this may vary slightly if different enclosures are used.

Installation Note

The system is intended to be installed by a professional electrician with experience in standby power. Please contact Hampshire Generators if you need any assistance. Hampshire Generators can also maintain your generator with a regular cost-effective service plan or one-off visit. Simply call 01329 722390 or inquire via contact us page for more information.

Read More

Component Manufacturer:

  • LVE or ESR

Amp Rating AC1:

  • 125 Amp

Requirement:

  • Residential Single Phase 230-240v

Delivery

When will I receive my order?

In most cases, a product on our website will give you an indication of the current stock availability, but shipping is not uniform for all products. We maintain fantastic relationships with all of our suppliers and we aim to get products to customers within 3 business days of the order being taken. This ava

...

When will I receive my order?

In most cases, a product on our website will give you an indication of the current stock availability, but shipping is not uniform for all products. We maintain fantastic relationships with all of our suppliers and we aim to get products to customers within 3 business days of the order being taken. This availability is based on information from our suppliers and from sales and supply patterns. The availability information given is a guide only and not a guarantee as there are external factors that we may not have control over.

Coronavirus Update – UK couriers and transport companies will not currently guarantee delivery times and we are seeing a slight delay in deliveries – please bear this in mind when ordering.

Specialist Couriers – Some items such as the larger portable power stations are sent by specialist courier as standard couriers will not accept them. These specialist couriers are very reliable but sometimes don’t have tracking or timed delivery.

Split deliveries – We sometimes need to send orders for more than one item by different courier networks (portable power stations for example) – so you may receive items at different times.

1500rpm machines or larger diesel gensets however are typically priced on application and all depend on the destination. We will be happy to quote on any large diesel generator and discuss your needs over the phone or via email.

Most orders placed before 12pm on a business day will be shipped from our suppliers on the same day provided the product is in stock. If you need to be certain an item is in stock and available, or if you need a lead time, it’s worth calling our sales team on 01329 722390. Pricing for extended shipping areas like Northern Ireland, the Scottish Highlands and outlying Islands, Outer Hebrides, Channel Islands, Isle of Man, Scilly Isles, and other postcodes not considered as UK mainland can be obtained also by calling our offices.

Please note that the processing of a payment and acknowledgement email does not constitute a legally binding contact. In the case of mispricing, changes in stock quantity, or if we believe the machine will be misused, we reserve the right to cancel the order and provide a full refund.

Heavy Items

You will be contacted by phone after ordering a larger item to confirm a delivery date before your order is dispatched. Large or heavy items are dispatched through a pallet network, so if we can’t get in contact with you, we may be unable to send out your item on a next day delivery. Please be sure to include a working phone number with your order.

Heavy items will require the recipient to make arrangements to take delivery of the goods and may require the recipient to help the courier unload the item. For items that are delivered on a pallet the courier will leave the pallet as close to your door as possible.

1500rpm diesel generators will require forklift (or similar) offloading; if this is not available then we can arrange a Hiab offload at an additional price – please call us to discuss any delivery requirements.

Read More

Have any questions on the Generator 125A Manual Transfer Switch Single Phase?

Get in touch with us today and we'll be happy to answer any questions you have.

  • CALL US

    01329 722390

  • EMAIL

    info@hampshiregenerators.co.uk

Need Expert Advice on the Generator 125A Manual Transfer Switch Single Phase?


This field is hidden when viewing the form
newsletter
acceptance(Required)
This field is for validation purposes and should be left unchanged.

Sign up to our Newsletter

  • This field is for validation purposes and should be left unchanged.